Plate size: 35 x 50 cm (14" x 20") System functions: back, main and post-exposure with UVC, washout, drying
Power supply: 220V- 2500W (13 Amp) – 2 phases – 2.5 KW Pipe fittings: cock with ball valve of 3/8 and 1
Features: - Exposure:
The drawer is provided with 8 lamps for the main exposure type UV 40W 10R, 5 lamps for the post-exposure type UV 40W and 4 lamps for the UVC exposure type TUV 15W. The microprocessor system keeps an internal memory of the lamps life to help determine when it's time to replace them. The vacuum system and the vacuum sheet perfectly hold the negative to the plate. The lamps and the vacuum surface are cooled by forced air circulation inside the drawer.
- Washout: the stainless steel tank has a capacity of 20 lt. approx. The nylon brushes are assembled on springs to have an even pressure on plates of
various thickness. The plate holder rotates alternatively in two directions to ensure an even washout of the plate and it stops if the lid is opened.
- Programming:
the microprocessor controlled keyboard allows the use to set up to nine customized programs to control time and temperature of each function: back exposure, main exposure, post-exposure and UVC, washout and drying.
- Green/red warning LEDs constantly informing about the status of the machine – acoustic alarm in case of errors and/or misfunctions.
- Dryer: the two drawers are provided with a 1000W heater, forced air circulation and safety switch.
- An exhausting system
extracts the solvent fumes from the washout, the exposure and the dryer.
|